An inverter MOSFET burns when electrical or thermal stress exceeds the device’s limits. Common paths include bridge shoot-through, drain-voltage overshoot, inadequate gate drive, excessive load current and operation outside the safe operating area. The failure time matters: a device destroyed at startup needs a different investigation from one that fails after warm-up. Replacing the MOSFET without checking its driver and commutation loop can repeat the same failure immediately.

Use the failure timing to choose the first measurement
A shorted drain–source pair confirms damage, not the initiating cause. Gate rupture, cracked packages and an open bond wire can all be secondary consequences. The guide to MOSFET failure modes explains why appearance alone is inconclusive.
| When the failure happens | First hypotheses | Evidence to collect |
|---|---|---|
| Before PWM starts | Wrong pinout, reversed device, shorted bus, damaged driver | Unpowered resistance checks and driver supply polarity |
| At the first switching edges | Cross conduction, false turn-on, severe ringing | Both gate-to-source waveforms and drain voltage |
| During motor startup or a load step | Overcurrent, transformer saturation, current-limit delay | Current waveform and protection response time |
| After several minutes | Loss underestimated, poor cooling, hot RDS(on), weak drive | Gate supply, case temperature and steady-state current |
| During shutdown or regeneration | DC-link rise, inductive energy, missing clamp path | Bus voltage, current direction and clamp behavior |
Battery-fed inverters can deliver destructive fault current even at a nominally low bus voltage. Mains-connected and high-voltage DC-link hardware requires appropriate isolation, discharge procedures and qualified test equipment. Do not attach an earth-referenced oscilloscope ground to a floating switch node. Use a suitable differential or isolated measurement system with verified voltage and common-mode ratings.
Eliminate shoot-through before increasing power
In a half bridge, the upper and lower switches must not conduct simultaneously across the DC link. Commanded dead time is only part of the answer. Driver propagation delay, mismatched turn-off times, Miller coupling, source inductance and bootstrap behavior determine the actual gate voltages at the device pins.
Check both VGS waveforms relative to their own source terminals. For the high-side device, measuring gate voltage relative to system ground does not establish VGS. Check startup, minimum pulse width, duty-cycle extremes and shutdown as well as steady operation. A bootstrap driver may lose gate bias under operating conditions that give its bootstrap capacitor insufficient recharge time.
A low-going command at the controller does not prove the MOSFET is off. Rapid drain-voltage change can push displacement current through CGD and raise the gate. TI’s gate-driver guidance describes strong turn-off paths and Miller clamps as possible countermeasures. Choose these from measured behavior and driver documentation; a large turn-on gate resistor alone is not a complete false-turn-on fix.
Calculate how a small commutation inductance creates a large spike
Consider an illustrative 48 V inverter. Suppose 20 A changes in 100 ns through an effective 100 nH commutation inductance. The inductive voltage magnitude is L × di/dt = 100 nH × 20 A / 100 ns = 20 V. Depending on the loop and switching edge, this can add to the bus stress, producing roughly 68 V before other ringing is considered.
This is already above a hypothetical 60 V MOSFET rating. It does not imply every 48 V inverter has that spike, or that selecting a particular higher rating automatically fixes the design. Measure worst-case bus voltage and overshoot, including charging conditions and regeneration, then choose suitable margin and a device supported by the complete loss and protection analysis.
Place high-frequency DC-link capacitance close to the bridge, minimize the commutation loop and examine clamp or snubber requirements. A very long probe loop can display a false spike, so verify the probe arrangement before drawing a device-selection conclusion.
Separate ordinary losses from a fault pulse
For an approximate hard-switching example, take VDS = 48 V, switching current 20 A, combined rise and fall time 160 ns and switching frequency 20 kHz. The overlap estimate Psw ≈ 0.5 × VDS × ID × (tr + tf) × fs gives about 1.54 W per device under those simplifying assumptions.
If the device’s RMS current is 10 A and its on-resistance at the actual gate voltage and junction temperature is 20 mΩ, conduction loss is approximately 2 W. Add diode conduction, reverse recovery, output-capacitance losses and any relevant avalanche energy. The estimate is a starting budget; real waveforms and modulation can change it substantially.
Several watts may explain gradual heating. They cannot describe a short shoot-through pulse solely by their average. A fault pulse must be evaluated using its simultaneous voltage, current, duration and the applicable SOA or short-circuit capability. Many MOSFETs do not have a guaranteed short-circuit withstand time.
Make protection faster than the damaging event
The MOSFET overcurrent-protection guide covers sensing and shutdown principles. For an inverter, verify the entire chain: sensor bandwidth, comparator threshold, blanking interval, logic response, driver propagation and gate discharge. A controller that eventually reports an error may still respond too slowly to save the switch.
Inspect the complementary device and gate driver after a failure. A damaged driver can hold the replacement partially on or expose its gate oxide to an excessive voltage. Check gate resistors, pull-downs, clamps, current shunts, insulation pads and source-return connections before re-energizing the bridge.
Use a documented, current-limited commissioning method appropriate to the inverter. Begin with driver supplies and verified control signals, then introduce a suitably limited bus and controlled load. Never assume an improvised current limiter or reduced bus voltage validates full-power safety. Some control loops and bootstrap circuits behave differently under those conditions.
Frequently asked diagnostic questions
Why does the heatsink stay cool when a MOSFET fails?
A localized junction event can occur faster than heat reaches the case or heatsink. A cool heatsink is not proof that the die stayed cool or that SOA was respected.
Will a higher-current replacement stop the failures?
Not necessarily. Headline current ratings do not determine gate charge, recovery behavior, package inductance or usable hot SOA. A larger device can overload a weak driver and switch more slowly.
Can longer dead time always prevent shoot-through?
It can address timing overlap, but it does not independently eliminate Miller-induced turn-on. Excessive dead time also increases diode conduction and can worsen commutation loss. Confirm actual waveforms before changing it.
For a replacement or a new bridge, compare the MOT power MOSFET range using bus stress, drive voltage, switching frequency, hot loss and fault timing. Share those conditions with MOT so component discussions start from the inverter’s actual requirements.