Rooted in China · Global discrete semiconductor supportGlobal semiconductor support

How Many Diodes Are in a Schottky Diode Package?

In this article

    A single Schottky diode has one rectifying metal–semiconductor junction. A dual Schottky package contains two diode elements, and a larger array can contain more. Pin count and package count alone do not give the number of usable diode paths. Read the datasheet symbol and use a diode-mode test to confirm the exact junction arrangement.

    Two-panel schematic comparing a single diode and a dual common-cathode network, with red meter probes on the anodes and the black probe on the shared cathode.
    The two forward checks on the common-cathode example use the same cathode pin. Check each anode separately and reverse the probes to confirm blocking at the meter’s test voltage.

    Count the diode symbols before counting the pins

    Begin with the full part number, including its suffix. Find the equivalent circuit and the pin table for that package. Count the diode symbols and identify where any nodes meet. Two leads marked with the same symbol may be connected together inside the package. A different three-lead part may bring out a common terminal, a series midpoint or an unused pin. The package drawing tells you where a terminal is located. The internal circuit tells you what the terminal does.

    Datasheet configurationNumber of diode elementsWhat connects inside the package
    Single1Anode and cathode form one rectifying path. An extra pin can be duplicated or unused.
    Dual common cathode2Cathodes join. Two separate anodes feed the shared node.
    Dual common anode2Anodes join. Two separate cathodes connect to the shared node.
    Dual series2One cathode connects to the other anode. The midpoint may be accessible.
    Isolated dual2Each diode has its own anode and cathode connection.

    On a power package, the exposed tab can be electrically connected to a shared node. Confirm the tab on the datasheet before placing the part on a heatsink or a copper land tied to another net. For a device in a small molded package, match the full marking with the manufacturer and package drawing. Board traces still help separate candidates that share an abbreviated mark. See how to identify a Schottky diode.

    Use a shared cathode to check both junctions

    Consider a three-pin device whose datasheet labels the independent terminals A1 and A2 and the shared terminal K. Disconnect power and verify the stored voltages have discharged. Use an isolated component or lift a lead as needed to remove misleading parallel paths. In the example below, a conventional digital meter applies positive diode-test voltage at the red probe.

    Red probeBlack probeExpected result on the isolated common-cathode part
    A1KForward reading for diode 1
    A2KForward reading for diode 2
    KA1, then A2Reverse blocking at the meter’s test voltage under ordinary conditions
    A1A2, then reverseNo ordinary forward path between the two anodes

    Keep the meter and device temperature consistent when comparing both junctions. Schottky forward readings depend on material, test current and temperature. The forward drop of a power device at its working current may differ substantially from a meter reading. For a common-anode part the positive probe stays on the common node instead. For a series pair, test both adjacent junctions individually if the midpoint is available. Across the outer pins a meter may have insufficient compliance voltage for two junctions, so an apparently open reading is inconclusive.

    A low reading in both directions on an isolated junction can indicate a hard short. The same readings on a populated PCB can come from a winding, parallel diode or low-resistance path. Check the second junction separately and compare with the schematic before replacing the device. See how to check a Schottky diode and how a Schottky diode fails.

    Check how the rectifier carries current

    A dual common-cathode package is often used as the output rectifier of a center-tapped secondary. Each anode connects to an opposite winding end, both cathodes feed the positive DC rail, and the center tap provides the return. One diode path feeds the output on each alternating half-cycle. There are two rectifier elements, but the conducting path contains one diode at a time in the idealized circuit. The full-wave rectifier comparison shows how that arrangement differs from a four-diode bridge.

    Ratings also require careful reading. A current in the part title may be the package total or a specified rating per diode. Check the manufacturer’s stated waveform, mounting conditions and temperature. Paralleling two diode elements can concentrate heat within the same package and one junction may take more current as the forward characteristics shift. Treat parallel operation as its own thermal design case, and use it only within the manufacturer’s stated conditions.

    Is a dual Schottky a bridge rectifier?

    Two diode elements can implement the center-tapped full-wave circuit when used with the required transformer. A conventional single-phase bridge needs four diode elements. A single molded bridge package can contain all four.

    If one junction is open, is the other automatically safe to reuse?

    No conclusion follows from that reading alone. One failed element can point to a shared thermal or surge event. Confirm both forward and reverse behavior and evaluate the original stress before selecting a replacement.

    For part selection, compare the exact junction configuration, repetitive reverse voltage, current and cooling assumptions in MOT’s planar Schottky range.

    Power Diodes View devices →